Standard Biochemical Assays: Protein Quantitation, ELISA, and Enzyme Kinetics

BCA and Bradford · Direct, indirect, sandwich ELISA · Michaelis–Menten Km and Vmax · Reporter gene assays

Published 2026 · Last updated 2026-09-27 · Hailu Zhou

These are the workhorse assays of a biochemistry lab, and they are the ones most often run on autopilot. Each rests on an assumption that is easy to violate: protein quantitation assumes the reference protein resembles your sample, ELISA assumes the standard curve behaves like the analyte, and enzyme kinetics assumes the initial rate is measured under conditions the model was derived for. Understanding the assumption is what lets you know when your number is wrong.

Protein quantitation: BCA versus Bradford versus A280

Total protein concentration is the denominator in almost every downstream comparison, so an error here propagates everywhere.

Always run the standard curve on the same plate, in the same buffer, as the samples. A standard curve in water applied to a sample in 1% SDS will be wrong by tens of percent. Prepare the standard in a buffer matched to the sample wherever possible.

ELISA formats and when to use each

ELISA converts an antibody-based recognition event into an enzymatic colorimetric or chemiluminescent signal. The format determines what can be measured:

Practical points that determine success: coat with the correct buffer pH (usually carbonate-bicarbonate, pH 9.6) and block with BSA or casein to prevent nonspecific binding; run standards and samples in duplicate or triplicate; and always determine the dynamic range. Most commercial kits report sensitivity as the detection limit, not the lower limit of quantification, and reading a sample in the flat portion of the curve produces a plausible but meaningless concentration.

Enzyme kinetics: Km and Vmax need care

Steady-state kinetics is described by the Michaelis–Menten equation, v = Vmax·[S] / (Km + [S]), where Km is the substrate concentration at half-maximal rate and Vmax is the rate at saturating substrate. Both are estimated from a substrate titration, ideally with at least six to eight concentrations bracketing Km, and with the rate measured during the initial linear phase of the reaction.

Choosing a linearisation is a real decision. The Lineweaver–Burk double-reciprocal plot is convenient but distorts the error structure and over-weights the lowest substrate points, which are the least reliable. Eadie–Hofstee and Hanes–Woolf plots are better behaved. Non-linear regression onto the Michaelis–Menten equation is the preferred modern method. With an inhibitor present, the same framework distinguishes competitive (Km increases, Vmax unchanged), non-competitive (both decrease), and uncompetitive (both decrease with a characteristic 1/v vs 1/[S] pattern) inhibition.

Kinetic constants also depend on the substrate used. Comparing Vmax values across studies run with different substrates or different assay temperatures is not comparing the same parameter, and the KM app notes for a given enzyme are only comparable within matched conditions.

Reporter gene assays

Reporter assays translate regulatory activity into an easily measured enzyme. Luciferase converts luciferin to oxyluciferin with emission at ~560 nm; β-galactosidase and β-lactamase are legacy alternatives; secreted alkaline phosphatase permits sampling of live cultures over time. The design should include an internal control, typically a constitutive Renilla luciferase, whose activity normalises for transfection efficiency and cell number. Without a co-transfected control, differences in reporter activity conflate regulatory effect with how much DNA entered the cell.

Assay conditions matter: luciferase signal is stable for a limited window and is sensitive to ATP and magnesium availability in the lysis reagent. Run each construct and condition in triplicate independent transfections, not triplicate wells of one transfection, because transfection efficiency varies between wells as well as between experiments. Report the ratio of experimental to control reporter and state the promoter construct in full, including the exact fragment boundaries, so the result can be reproduced.

References

  1. Smith PK, Krohn RI, Hermanson GT, et al. Measurement of protein using bicinchoninic acid. Anal Biochem. 1985;150(1):76–85.
  2. Bradford MM. A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. Anal Biochem. 1976;72:248–254.
  3. Compton SJ, Jones CG. Mechanism of dye response and interference in the Bradford protein assay. Anal Biochem. 1985;151(2):369–374.
  4. Engvall E, Perlmann P. Enzyme-linked immunosorbent assay (ELISA): quantitative assay of immunoglobulin G. Immunochemistry. 1971;8(9):871–874.
  5. Van Weemen BK, Schuurs AH. Immunoassay using antigen-enzyme conjugates. FEBS Lett. 1971;15(3):232–236.
  6. Michaelis L, Menten ML. Die Kinetik der Invertinwirkung. Biochem Z. 1913;49:333–369.
  7. Lineweaver H, Burk D. The determination of enzyme dissociation constants. J Am Chem Soc. 1934;56(3):658–666.
  8. Cornish-Bowden A. Fundamentals of Enzyme Kinetics. 4th ed. Weinheim: Wiley-Blackwell; 2012.
  9. de Wet JR, Wood KV, DeLuca M, et al. Firefly luciferase gene: structure and expression in mammalian cells. Mol Cell Biol. 1987;7(2):725–737.
  10. Brasier AR, Tate JE, Habener JF. Optimized use of the firefly luciferase assay as a reporter gene in mammalian cell lines. Biotechniques. 1989;7(10):1116–1122.